Opto Engineering® - 20 years
Home Optics Telecentric lenses TCDP PLUS series
TCDP23C4MC096
Specifications
Downloads
Compatible products
Main optical specifications
Magnification (x) 0.093
0.186
Image circle diameter (mm) 11.0
21.6
Max sensor size 2/3″
4/3″
Object field of view
1/2" (mm × mm) 68.82 x 51.61
34.41 x 25.81
2/3" (mm × mm) 91.40 x 76.24
45.70 x 38.12
1" (mm × mm) -
76.29 x 40.38
4/3″ (1) (mm × mm) -
101.77 x 57.04
Advanced optical specifications
Working distance (2) (mm) 278.6
278.6
Working ƒ/N (3) 8
16
Telecentricity typical (max) (4) (deg) < 0.06 (0.08)
< 0.05 (0.10)
Distortion typical (max) (5) (%) < 0.04 (0.08)
< 0.04 (0.10)
Depth of field (6) (mm) 47.90
23.90
Resolution (7) (μm) 55
55
Mechanical specifications
Mount C
C
Phase adjustment (8) Yes
Yes
Length (9) (mm) 337.5
H1 (10) (mm) 145.2
Front diameter (mm) 143.0
Mass (g) 2821

Last update 11 Sep 2023

REACH

Notes

  1. With IMX387 (21.7 mm diagonal) sensors, the FOV of TC4MHRyyy-x lenses may show some vignetting at the image corners.
  2. Working distance: distance between the front end of the mechanics and the object. Set this distance within +/- 3% of the nominal value for maximum resolution and minimum distortion.
  3. Working f-number (wf/N): the real f-number of a lens in operating conditions.
  4. Maximum angle between chief rays and optical axis on the object side. Typical (average production) values and maximum (guaranteed) values are listed.
  5. Percent deviation of the real image compared to an ideal, undistorted image. Typical (average production) values and maximum (guaranteed) values are listed.
  6. At the limits of the depth of field, the image can still be used for measurements. For a very sharp image, however, only half of the depth of field should be considered. Pixel size used for calculation is 3.45 μm.
  7. Object side, calculated with the Rayleigh criterion with λ= 520 nm
  8. Indicates the availability of an integrated camera phase adjustment feature.
  9. Measured from the front end of the mechanics to the camera flange.
  10. Right-angled ocular length, measured from the optical axis of the frontal lens to the camera flange
All product specifications and data are subject to change without notice to improve reliability, functionality, design or other. Photos and pictures are for illustration purposes only.

Technical documents

Product user guide
Back focal adjustment

Datasheet

Download datasheet

Layout files

DXF
IGS
PDF
STEP
SLDPRT
Despite the efforts made to generate an error-free compatibility list, we always recommend to consult the Opto Engineering® technical support department before purchasing a compatible product. Opto Engineering® shall not be liable for any damage or malfunctioning caused by the incorrect selection of a compatible product.
ITA50-GM-10C
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Mono, 1 GigE, POE, C mount
ITA50-GC-10C
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Color, 1 GigE, POE, C mount
ITA50-GM-10C-PL
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Polar Mono, 1 GigE, POE, C mount
ITA50-GC-10C-PL
Area scan camera 2464 x 2056 MP, Sony IMX264, CMOS Global shutter, 2/3", Polar Color, 1 GigE, POE, C mount
ITA81-GM-20C
Area scan camera 2856 x 2848 MP, Sony IMX546, CMOS Global shutter, 2/3", Mono, 1 GigE, POE, C mount
ITA81-GC-20C
Area scan camera 2856 x 2848 MP, Sony IMX546, CMOS Global shutter, 2/3", Color, 1 GigE, POE, C mount
LTCLHP096-R
Telecentric HP illuminator, beam diameter 120 mm, red, 625 nm
LTCLHP096-G
Telecentric HP illuminator, beam diameter 120 mm, green, 525 nm
LTCLHP096-B
Telecentric HP illuminator, beam diameter 120 mm, blue, 460 nm
LTCLHP096-W
Telecentric HP illuminator, beam diameter 120 mm, white, 6000 K
LTRN096RD
Ring LED illuminator, inner diameter 143.0 mm, straight type, red, 630 nm
LTRN096GR
Ring LED illuminator, inner diameter 143.0 mm, straight type, green, 525 nm
LTRN096BL
Ring LED illuminator, inner diameter 143.0 mm, straight type, blue, 470 nm
LTRN096NW
Ring LED illuminator, inner diameter 143.0 mm, straight type, white, 6300 K
CMBS series
CMBS series
45° beam splitters
CMBS096
45° beam splitter with mount for 143.0 mm clamping diameter optics
CMMR series
CMMR series
45° first surface mirrors
CMMR096
45° first surface mirror for 143.0 mm clamping diameter optics
WI series
WI series
Protective windows for lenses
WI096
Protective window for 143 mm clamping diameter optics
CMHO series
CMHO series
Clamping mechanics for lenses
CMHO096
Clamping mechanics for TCxx085, TCxx096 lenses and LTCLHP096-X illuminators
PT064-096
Calibration pattern
PT064-096-C
Checkerboard calibration pattern for telecentric lens with certificate
PT064-096-P
Calibration pattern
CMWF series
CMWF series
Holders for WI series
CMWF096
Holder for WI series, clamping diameter 143 mm
Request a quote