| Main optical specifications |
|
Image circle diameter
|
(mm) |
10.4
|
|
Min sensor size
|
|
1.1"
|
| Field of view (diameter x height) |
|
Minimum
|
(mm × mm) |
2.5 x 6.0
|
|
Maximum
|
(mm × mm) |
10.0 x 1.0
|
| Advanced optical specifications |
|
Working distance with minimum object
(1)
|
(mm) |
5.0
|
|
Working distance with maximum object
(1)
|
(mm) |
1.5
|
|
Angle of view
|
(deg) |
37
|
|
Working ƒ/N
(2)
|
|
11
|
| Lighting specifications |
|
Light color, peak wavelength
|
|
white, 6000 K
|
|
Number of LEDs
|
|
12
|
| Electrical specifications |
|
Supply voltage
(3, 4)
|
(V) |
24
|
|
Current
(4)
|
(mA) |
450
|
|
Power consumption
(4)
|
(W) |
10.8
|
|
Typical pulse voltage
(5)
|
(V) |
35
|
|
Max pulse current
(3, 5)
|
(mA) |
1000
|
|
Peak power consumption
(5)
|
(W) |
35
|
|
Max duty-cycle
(5)
|
(%) |
1
|
|
Max pulse duration
(5)
|
(ms) |
10
|
|
Estimated MTBF
(6)
|
(hours) |
> 50000
|
|
Cable length
|
(m) |
1.5
|
|
Connector
|
|
flying leads
|
| Eye safety |
|
Risk group according to CEI EN 62471:2010
|
|
Risk Group 2
|
| Mechanical specifications |
|
Mount
|
|
C
|
|
Length
(7)
|
(mm) |
301.3
|
|
Width
|
(mm) |
119.0
|
|
Height
|
(mm) |
139.5
|
|
Mass
|
(g) |
1577
|
| Environmental specifications |
|
Operating temperature
|
(°C) |
0-40
|
|
Storage temperature
|
(°C) |
0-50
|
|
Operating relative humidity
|
(%) |
20-85, non condensing
|
|
Installation
|
|
Indoor use only
|
Notes
- Working distance: distance between the front end of the mechanics and the object.
- Working f-number (wf/N): the real f-number of a lens in operating conditions.
- Tolerance ± 2%.
- Continuous mode
- Pulsed mode
- Drop to 50% intensity @ 25°C.
- Measured from the front end of the mechanics to the camera flange.
All product specifications and data are subject to change without notice to improve reliability, functionality, design or other. Photos and pictures are for illustration purposes only.