Opto Engineering® - 20 years
Home Optics Telecentric lenses TC12K series
TC12K240
Specifications
Downloads
Compatible products
Main optical specifications
Magnification (x) 0.260
Image circle diameter (mm) 62.4
Max sensor size 12k/16k
Object field of view
Line 8k-7µm (mm) 220.38
Line 16k-3.5µm (mm) 220.38
Line 12k-5µm (mm) 236.15
Line 12k-5.2µm (mm) 240.00
Advanced optical specifications
Working distance (1) (mm) 492.8
Working ƒ/N (2) 16
Telecentricity typical (max) (3) (deg) < 0.06 (0.08)
Distortion typical (max) (4) (%) < 0.08 (0.10)
Depth of field (5) (mm) 24.90
Resolution (6) (μm) 39
Mechanical specifications
Mount (7) M72x0.75 FD 6.56
Phase adjustment (8) Yes
Length (9) (mm) 1072.8
Front diameter (mm) 322
Mass (g) 19514

Last update 05 Sep 2023

REACH

Notes

  1. Working distance: distance between the front end of the mechanics and the object. Set this distance within ±3% of the nominal value for maximum resolution and minimum distortion.
  2. Working f-number (wf/N): the real f-number of a lens in operating conditions.
  3. Maximum angle between chief rays and optical axis on the object side. Typical (average production) values and maximum (guaranteed) values are listed.
  4. Percent deviation of the real image compared to an ideal, undistorted image. Typical (average production) values and maximum (guaranteed) values are listed.
  5. At the borders of the field depth the image can be still used for measurement but, to get a very sharp image, only half of the nominal field depth should be considered. Pixel size used for calculation is 7 μm.
  6. Object side, calculated with the Rayleigh criterion with λ= 520 nm
  7. FD stands for Flange Distance (in mm), defined as the distance from the mounting flange (the “metal ring” in rear part of the lens) to the camera detector plane.
  8. Indicates the availability of an integrated camera phase adjustment feature.
  9. Measured from the front end of the mechanics to the camera flange.
All product specifications and data are subject to change without notice to improve reliability, functionality, design or other. Photos and pictures are for illustration purposes only.

Technical documents

Product user guide
Back focal adjustment

Datasheet

Download datasheet

Layout files

DXF
IGS
PDF
STEP
SLDPRT
Despite the efforts made to generate an error-free compatibility list, we always recommend to consult the Opto Engineering® technical support department before purchasing a compatible product. Opto Engineering® shall not be liable for any damage or malfunctioning caused by the incorrect selection of a compatible product.
LTCLHP240-R
Telecentric HP illuminator, beam diameter 300 mm, red, 625 nm
LTCLHP240-G
Telecentric HP illuminator, beam diameter 300 mm, green, 525 nm
LTRN240RD
Ring LED illuminator, inner diameter 322.0 mm, straight type, red, 630 nm
LTRN240GR
Ring LED illuminator, inner diameter 322.0 mm, straight type, green, 525 nm
LTRN240BL
Ring LED illuminator, inner diameter 322.0 mm, straight type, blue, 470 nm
LTRN240NW
Ring LED illuminator, inner diameter 322.0 mm, straight type, white, 6300 K
CMHO series
CMHO series
Clamping mechanics for lenses
CMHO240R
Clamping mechanics for TCxx240 lenses and LTCLHP240-X illuminators
PT192-240
Calibration pattern
PT192-240-C
Checkerboard calibration pattern for telecentric lens with certificate
PT192-240-P
Calibration pattern
Request a quote
Add this product to the quote request list.